Features and Benefits of our Desiccant Air Dryers:
- A heavy-duty, skid-mounted portable design for indoor or outdoor installation and field application
- Rugged design for rental fleets market
- Instrument quality air with Adjustable flow requirements and pressure dew point
- Remove moisture that can lead to rust, corrosion, ice buildup, contaminants, and wear and tear of moving compressor parts
- Special paint coating for extreme outdoor and coastal environments
- Forklift holes and lifting lugs for easy transportation
- Fabricated with dimensions to fit on trucks and in ISO (Conex containers)
- Optional Romar ALL STEEL Silencer vs. standard muffler (Patent Number: 11578714)
- NEMA 4X, 115/1/60 electrics suitable for outdoor operation
- Single-point electrical connection via cord set (less than two amps)
- Hour meter and easy plug-and-play installation
- Dryer/After Cooler combo available on some designs
- IDEC smart relay in control board
- Dew points of -40°F to -100°F
- Low pressure or high pressure design on most models
FILTRATION
Romar Air Dryers have three levels of filtration to meet compressed air quality standards:
- Water Separator Coarse Pre-filter: Specially designed for the efficient removal of bulk liquid contamination from compressed air. 1.0μ to remove moisture and oil*
- Fine Pre-filter: .01micron to remove moisture and oil, protects dryer desiccant from contamination*
- After-filter: 1.0 micron, removes particulates, protects downstream equipment.
*use float drain
BASIC CONTROLLER FEATURES
- Nema 4X enclosure
- LCD user interface
- Four line digital display features
1) Tower drying cycle
2) Tower regenerating indication
3) Run status
4) Time remaining in cycle - Selectable cycle settings
- Power ON/OFF switch
ROMAR leads the way in improving Desiccant Air Dryers
YOU CAN COUNT ON OUR RELIABLE DESIGN WITH SPECIAL FEATURES - Patent Number: 11578714
ROMAR's ALL STEEL Silencer vs. other's Standard Muffler
Quieter, tougher and stronger to stand up in the field. Virtually no maintenance is needed and there are virtually no replacement costs. (Patent Number: 11578714)
Custom Colors Are Available! Let Us Know What You Prefer!
Colors are important to supporting a company's brand. Our air dryers offer custom solutions depending on your need and the same is true with the appearance. Custom colors are available. Just let us know how we can help you. (Click on the thumbnails below to see a larger image)
PORTABLE FILTER PACKAGE
MODEL F5400
High Efficiency Filters - removes aerosols and solids to .01 micron (.01 ppm w/w maximum remaining oil content). Drains automatic with manual adjustment.
Model F5400 - Inlet Conditions | |
---|---|
Flow (CFM) | 5400 CFM @ 100 PSIG |
Maximum Inlet Pressure | 165 PSIG |
Maximum inlet temperature | 120 degree F |
Model F5400 - Outlet Conditions | |
---|---|
Removal of solid particles | 1 Micron (or .01 Micron Option) |
Removal of oil vapor | 1 PPM (or .01 PPM Option) |
Dimensions: L/W/H | 71” x 38” x 84” |
In & Out Connections | Inlet (4) 3” Boss Outlet (4) 3” Boss |
Weight | 1,800 lb. |
AVAILABLE MODELS
ROMAR 450LP (250psi)
(with aftercooler)
RD450 - Technical Information | |||
---|---|---|---|
Flowrate @ 100psi g (scfm) | Dryer Air In/Out | Max. Operating Pressure - psi | Max. Operating Pressure - bar |
450 | 2" NPT | 250 | (17) |
RD450 - Dimensions | |||||||
---|---|---|---|---|---|---|---|
Height | Width | Depth | Weight | ||||
in | mm | in | mm | in | mm | lbs | kg |
83 | 2108 | 47 | 1193 | 71 | 1803 | 2200 | 998 |
RD450 - Temperatures | |||||
---|---|---|---|---|---|
Max. Inlet Compressed Air Temperature | Min. Ambient Temperature | Max. Ambient Temperature | |||
℉ | ℃ | ℉ | ℃ | ℉ | ℃ |
120 | (49) | 40 | (4) | 105 | (41) |
RD450 - Electrical Parameters | |
---|---|
Power Supply | 120v/1ph/60Hz |
RD1000 - Technical Information | |||
---|---|---|---|
Flowrate @ 100psi g (scfm) | Dryer Air In/Out | Max. Operating Pressure - psi | Max. Operating Pressure - bar |
1000 | 3" NPT | 250 | (17) |
RD1000 - Dimensions | |||||||
---|---|---|---|---|---|---|---|
Height | Width | Depth | Weight | ||||
in | mm | in | mm | in | mm | lbs | kg |
83 | 2108 | 70 | 1778 | 74 | 1879 | 4500 | 2041 |
RD1000 - Temperatures | |||||
---|---|---|---|---|---|
Max. Inlet Compressed Air Temperature | Min. Ambient Temperature | Max. Ambient Temperature | |||
℉ | ℃ | ℉ | ℃ | ℉ | ℃ |
120 | (49) | 40 | (4) | 105 | (41) |
RD1000 - Electrical Parameters | |
---|---|
Power Supply | 120v/1ph/60Hz |
ROMAR 1000LP (250psi)
(with or without aftercooler)
ROMAR 1000HP (350psi)
(with or without aftercooler)
RDH1000 - Technical Information | |||
---|---|---|---|
Flowrate @ 100psi g (scfm) | Dryer Air In/Out | Max. Operating Pressure - psi | Max. Operating Pressure - bar |
1000 | 3" NPT | 350 | (23.80) |
RDH1000 - Dimensions | |||||||
---|---|---|---|---|---|---|---|
Height | Width | Depth | Weight | ||||
in | mm | in | mm | in | mm | lbs | kg |
83 | 2108 | 70 | 1778 | 74 | 1879 | 4500 | 2041 |
RDH1000 - Temperatures | |||||
---|---|---|---|---|---|
Max. Inlet Compressed Air Temperature | Min. Ambient Temperature | Max. Ambient Temperature | |||
℉ | ℃ | ℉ | ℃ | ℉ | ℃ |
120 | (49) | 40 | (4) | 105 | (41) |
RDH1000 - Electrical Parameters | |
---|---|
Power Supply | 120v/1ph/60Hz |
RDUH1000 - Technical Information | |||
---|---|---|---|
Flowrate @ 100psi g (scfm) | Dryer Air In/Out | Max. Operating Pressure - psi | Max. Operating Pressure - bar |
1000 | 3" NPT | 500 | (34.47) |
RDUH1000 - Dimensions | |||||||
---|---|---|---|---|---|---|---|
Height | Width | Depth | Weight | ||||
in | mm | in | mm | in | mm | lbs | kg |
83 | 2108 | 70 | 1778 | 74 | 1879 | 4500 | 2041 |
RDUH1000 - Temperatures | |||||
---|---|---|---|---|---|
Max. Inlet Compressed Air Temperature | Min. Ambient Temperature | Max. Ambient Temperature | |||
℉ | ℃ | ℉ | ℃ | ℉ | ℃ |
120 | (49) | 40 | (4) | 105 | (41) |
RDUH1000 - Electrical Parameters | |
---|---|
Power Supply | 120v/1ph/60Hz |
ROMAR 1000UHP (500psi)
ROMAR 1600LP (250psi)
(with or without aftercooler)
RD1600 - Technical Information | |||
---|---|---|---|
Flowrate @ 100psi g (scfm) | Dryer Air In/Out | Max. Operating Pressure - psi | Max. Operating Pressure - bar |
1600 | 3" NPT | 250 | (17) |
RD1600 - Dimensions | |||||||
---|---|---|---|---|---|---|---|
Height | Width | Depth | Weight | ||||
in | mm | in | mm | in | mm | lbs | kg |
88.75 | 2254 | 81.5 | 2070 | 75.75 | 1924 | 5000 | 2267 |
RD1600 - Temperatures | |||||
---|---|---|---|---|---|
Max. Inlet Compressed Air Temperature | Min. Ambient Temperature | Max. Ambient Temperature | |||
℉ | ℃ | ℉ | ℃ | ℉ | ℃ |
120 | (49) | 40 | (4) | 105 | (41) |
RD1600 - Electrical Parameters | |
---|---|
Power Supply | 120v/1ph/60Hz |
RDH1600 - Technical Information | |||
---|---|---|---|
Flowrate @ 100psi g (scfm) | Dryer Air In/Out | Max. Operating Pressure - psi | Max. Operating Pressure - bar |
1600 | 3" NPT | 350 | (23.80) |
RDH1600 - Dimensions | |||||||
---|---|---|---|---|---|---|---|
Height | Width | Depth | Weight | ||||
in | mm | in | mm | in | mm | lbs | kg |
88.75 | 2254 | 81.5 | 2070 | 75.75 | 1924 | 5000 | 2267 |
RDH1600 - Temperatures | |||||
---|---|---|---|---|---|
Max. Inlet Compressed Air Temperature | Min. Ambient Temperature | Max. Ambient Temperature | |||
℉ | ℃ | ℉ | ℃ | ℉ | ℃ |
120 | (49) | 40 | (4) | 105 | (41) |
RDH1600 - Electrical Parameters | |
---|---|
Power Supply | 120v/1ph/60Hz |
ROMAR 1600HP (350psi)
(with or without aftercooler)
ROMAR 3000LP (150psi)
RD3000 - Technical Information | |||
---|---|---|---|
Flowrate @ 100psi g (scfm) | Dryer Air In/Out | Max. Operating Pressure - psi | Max. Operating Pressure - bar |
3000 | 3" NPT/4"FLg | 175 | (11.90) |
RD3000 - Dimensions | |||||||
---|---|---|---|---|---|---|---|
Height | Width | Depth | Weight | ||||
in | mm | in | mm | in | mm | lbs | kg |
86.5 | 2197 | 90 | 2286 | 115.5 | 2933 | 9200 | 4173 |
RD3000 - Temperatures | |||||
---|---|---|---|---|---|
Max. Inlet Compressed Air Temperature | Min. Ambient Temperature | Max. Ambient Temperature | |||
℉ | ℃ | ℉ | ℃ | ℉ | ℃ |
120 | (49) | 40 | (4) | 105 | (41) |
RD3000 - Electrical Parameters | |
---|---|
Power Supply | 120v/1ph/60Hz |
RDH3000 - Technical Information | |||
---|---|---|---|
Flowrate @ 100psi g (scfm) | Dryer Air In/Out | Max. Operating Pressure - psi | Max. Operating Pressure - bar |
3000 | 3" NPT/4"FLg | 350 | (24.13) |
RDH3000 - Dimensions | |||||||
---|---|---|---|---|---|---|---|
Height | Width | Depth | Weight | ||||
in | mm | in | mm | in | mm | lbs | kg |
86.5 | 2197 | 90 | 2286 | 115.5 | 2933 | 9200 | 4173 |
RDH3000 - Temperatures | |||||
---|---|---|---|---|---|
Max. Inlet Compressed Air Temperature | Min. Ambient Temperature | Max. Ambient Temperature | |||
℉ | ℃ | ℉ | ℃ | ℉ | ℃ |
120 | (49) | 40 | (4) | 105 | (41) |
RDH3000 - Electrical Parameters | |
---|---|
Power Supply | 120v/1ph/60Hz |
ROMAR 3000HP (350psi)
ROMAR 5400HP (150psi)
RD5400 - Technical Information | |||
---|---|---|---|
Flowrate @ 100psi g (scfm) | Dryer Air In/Out | Max. Operating Pressure - psi | Max. Operating Pressure - bar |
5400 | 3" NPT/6"FLg | 150 | (10.34) |
RD5400 - Dimensions | |||||||
---|---|---|---|---|---|---|---|
Height | Width | Depth | Weight | ||||
in | mm | in | mm | in | mm | lbs | kg |
88.5 | 2248 | 91 | 2311 | 163 | 4140 | 16000 | 7257 |
RD5400 - Temperatures | |||||
---|---|---|---|---|---|
Max. Inlet Compressed Air Temperature | Min. Ambient Temperature | Max. Ambient Temperature | |||
℉ | ℃ | ℉ | ℃ | ℉ | ℃ |
120 | (49) | 40 | (4) | 105 | (41) |
RD5400 - Electrical Parameters | |
---|---|
Power Supply | 120v/1ph/60Hz |
Our commitment is to you and our products. Call Romar Air Dryers today!
We are continually researching innovative ways to improve the efficiency and reliability of our existing line of desiccant air dryers while also looking into the future at what could come next. Our commitment is to our customers, and because of that, we will never stop evolving our products and services to meet your needs. Call Romar Air Dryers today!